- It is mainly used on delivery room, baby wards, N ICU that the baby’s maximum weight up to 10 KG.
- Adjust the Oxygen concentration from 21% to 100%
- The MAX-P and PIP are safe, controlled and accurate.
- The PEEP is constant and accurate.
- Simple operation and flexible application.
- The output pressure would not be influenced by the
operator experience, training, attention and fatigue.
Resuscitation Trolley
BRAND – mLabs
Baby Bassinet with a big shelf at the bottom for keeping consumables.
Related Products
Oxygen Concentrator 5 Ltr.
* Flow Rate 0.5-5L/min
* Outlet Pressure 6-10 PSI (0.04-0.07 Mpa)
* Net Weight 16Kgs
* Sound Level ≤40dB
* Power Consumption ≤350W
* Input Frequency 50Hz; 60Hz
* Put Voltage AC230V ± 10%; AC110V ±10%
* Alarm 1. Power failure alarm;
2. High and low pressure alarm;
3. Low oxygen purity alarm:
When oxygen purity is >82%, blue light illuminates;
When oxygen purity is < 82%, red light illuminates for indicating low purity;
4. Low flow alarm;
Optional
• Nebulizer (Atomizer)
• Low concentration alarm: when oxygen concentration is 82% or above, the green light will be on; when the oxygen concentration is blow 82%, the red light will be on.
• Maintenance alarm: alarm for maintenance after 3000 hours' operation.
• High temperature alarm: alarm for high temperature when the internal system temperature is above 50°C.
• Pulse oximeter: fingertip pulse oximeter is available for monitoring patient's oxygen saturation on site.
• Small LCD display: showing accumulated time, present working time and preset time.
Medical Air Compressor – mLabs – 3000
BRAND – mLabs
Air Compressor with Digital Display
- Delivers dry, clean medical-grade compressed air
- Optional cost-performance ratio
- Quiet performance suitable for use in any ICU / N ICU
- It can be used either as a primary air source or as an automatic backup to a hospital’s air pipeline system for medical ventilator and bubble CPAP units
Digital Vacuum Oven
- Capacity – 24 Ltr.
- Temperature Range ºC – Ambient + 10- 250ºC
- Temperature Resolution ºC – 0.1ºC
- Temperature Uniformity – + 1%
- Inner Dimension (cm) WxDxH – 30x30x27
- Outer Dimension (cm) WxDxH – 48x48x60
- Power Wattage – 800 W
- Vacuum degree – 220V / 50Hz
- Gross Weight – 55 kg
Infant Radiant Warmer – mLabs – S
BRAND – mLabs
The digital, micro processor – based controller comes with a full spectrum of features. Two function control modes provide the clinician more flexibility while optimizing the thermal environment. Dual digital temperature displays allow easy visualization of patient temperature and set point.
Infant Radiant Warmer – mLabs – DX (E)
BRAND – mLabs
Range of mLabs– DX(E) Infant Radiant Warmer allow you to efficiently care and provide advance warming capabilities while using one touch operations to simplify procedures. Advance microprocessor controlled system with self-check on the electronic circuitry skin /air/ manual control.
Open Care System – mLabs – DX
BRAND – mLabs
Range of mLabs – DX open care systems allow you to efficiently care and provide advance warming capabilities while using one touch operations to simplify procedures. Advance microprocessor controlled system with self check on the electronic circuitry skin / air / manual control.
Oxygen Concentrator 10 Ltr.
* Flow Rate 0.10- 10L/min
* Outlet Pressure 6-10 PSI (0.04-0.07 Mpa)
* Net Weight 16Kgs
* Sound Level ≤40dB
* Power Consumption ≤350W
* Input Frequency 50Hz; 60Hz
* Put Voltage AC230V ± 10%; AC110V ±10%
* Alarm 1. Power failure alarm;
2. High and low pressure alarm;
3. Low oxygen purity alarm:
When oxygen purity is >82%, blue light illuminates;
When oxygen purity is < 82%, red light illuminates for indicating low purity;
4. Low flow alarm;
Optional
• Nebulizer (Atomizer)
• Low concentration alarm: when oxygen concentration is 82% or above, the green light will be on; when the oxygen concentration is blow 82%, the red light will be on.
• Maintenance alarm: alarm for maintenance after 3000 hours' operation.
• High temperature alarm: alarm for high temperature when the internal system temperature is above 50°C.
• Pulse oximeter: fingertip pulse oximeter is available for monitoring patient's oxygen saturation on site.
• Small LCD display: showing accumulated time, present working time and preset time.
mLabs Phototherapy Unit 24 LED Single Surface
BRAND – mLabs
In the new born period i.e. birth to one month, jaundice can pose a serious problem, because high level of the bilirubin, which is not water soluble, can be decomposed to a harmless metabolic which is water soluble, does not cross blood brain barrier and is rapidly excreted in the bile and urine and so does not accumulate .
Baby Incubator mLabs – 1723D
BRAND – mLabs
- The temp. controlled unit is operated by advanced micro computer technology.
- The three digital display indication provide the Set Temperature, Air Temperature and Skin Temperature.
- Two function control modes provide the clinician more flexibility while optimizing the thermal environment.
- In addition the skin temperature is display is larger than the set / air temperature display.
- The removable heater and control unit make it easy to clean and service.
- Full visibility & accessibility of the baby is provided by the designed of acrylic hood.
Open Care System – mLabs – D
BRAND – mLabs
Range of mLabs – D, open care system that comes in fiber and powder coated MS allow you to efficiently care and provide advance warming capabilities while using one touch operations to simplify procedures. Advance microprocessor controlled system with self-check on the electronic circuitry skin / air / manual control. Latest circuitry Skin/Air/Manual control. Latest technology packed with higher accuracy & enhanced visibility has been integrated in the system
Medical Air Compressor – mLabs – 1000
BRAND – mLabs
Air Compressor for Ventilator & Bubble CPAP
- Delivers dry, clean medical-grade compressed air
- Optional cost-performance ratio
- Quiet performance suitable for use in any ICU / N ICU
- It can be used either as a primary air source as a primary air source or as an automatic backup to a hospital’s air pipeline system for medical ventilator and bubble CPAP units
mLabs Phototherapy Unit 24 LED Double Surface
BRAND – mLabs
In the new born period i.e. birth to one month, jaundice can pose a serious problem, because high level of the bilirubin, which is not water soluble, can be decomposed to a harmless metabolic which is water soluble, does not cross blood brain barrier and is rapidly excreted in the bile and urine and so does not accumulate .