Oxygen Concentrator we provide is classified into the ordinary type and the low-noise type. The two types of oxygen gas generators have the same parameters except that the low-noise type one has smaller size, lighter weight and makes lower noises while working. Price of the low-noise type one is slightly higher than the ordinary type one. Our oxygen concentrating machine is energy-saving and safe to use. The optional dual-flow configuration allows two users to inhale oxygen at the same time by sharing one machine.
Oxygen Concentrator 5 Ltr.
* Flow Rate 0.5-5L/min
* Outlet Pressure 6-10 PSI (0.04-0.07 Mpa)
* Net Weight 16Kgs
* Sound Level ≤40dB
* Power Consumption ≤350W
* Input Frequency 50Hz; 60Hz
* Put Voltage AC230V ± 10%; AC110V ±10%
* Alarm 1. Power failure alarm;
2. High and low pressure alarm;
3. Low oxygen purity alarm:
When oxygen purity is >82%, blue light illuminates;
When oxygen purity is < 82%, red light illuminates for indicating low purity;
4. Low flow alarm;
Optional
• Nebulizer (Atomizer)
• Low concentration alarm: when oxygen concentration is 82% or above, the green light will be on; when the oxygen concentration is blow 82%, the red light will be on.
• Maintenance alarm: alarm for maintenance after 3000 hours' operation.
• High temperature alarm: alarm for high temperature when the internal system temperature is above 50°C.
• Pulse oximeter: fingertip pulse oximeter is available for monitoring patient's oxygen saturation on site.
• Small LCD display: showing accumulated time, present working time and preset time.
Related Products
Infant Radiant Warmer – mLabs – IRW 1723
BRAND – mLabs
Advance micro processor controlled system with self check on the electronic circuitry skin / Air Manual control. Digital display of baby temperature.
Medical Air Compressor – mLabs – 1000
BRAND – mLabs
Air Compressor for Ventilator & Bubble CPAP
- Delivers dry, clean medical-grade compressed air
- Optional cost-performance ratio
- Quiet performance suitable for use in any ICU / N ICU
- It can be used either as a primary air source as a primary air source or as an automatic backup to a hospital’s air pipeline system for medical ventilator and bubble CPAP units
Oxygen Analyzer
BRAND – mLabs
It is a kind of device that can detect the oxygen concentration continuously. It adopts the imported solid oxygen electrode, with good reaction. It can match with the devices such as hood, incubator, CPAP, hyperbaric oxygen chamber, ventilator or anesthesia machine, oxygen makers.
Bubble CPAP Machine – Restohealth mLabs – 03
BRAND – mLabs
Newborn / Pediatric CPAP Continuous Positive Airway Pressure Ventilation Support System.
Additional Feature
- With inbuilt Air-oxygen blender.
- Compact, easy to carry with built in handle on the top.
- Can be used as transport CPAP, if attached to power-supply and oxygen.
- New concept free built-in air compressor easy BUBBLE CPAP.
- Low power design for spontaneous breathing of newborns and children, to provide continuous positive pressure ventilation support.
- Small size, low noise, maintenance-free for N ICU, transport, pediatric ward and other different place.
Double Dome Ceiling OT Light
Technical Data
- Number of LED : 105 X2
- Intensity : 2,00,000 x 2 Lux
- Diameter of Light : 10-100 Digital
- Spot Diameter : 100- 150 mm
- Depth Lumination – 10-15cm
- Colour Temp. : 3800-5200K
- Colour Rendering Index : 91 Ra
- Focusing : Fix
- LED Average Life : >50000 Hrs.
- Intensity Control : 560mm X 2
- Power Supply : 220V/50Hz AC
- Power : 120 Watt X 2
- Special Function : 5 Memory Function
Colour Specification – Multi Colour
Positioning – Ceiling Mounted,Modular,Mobile,Wall Mounted
Bubble CPAP Machine – Restohealth mLabs – 02
BRAND – mLabs
Newborn / Pediatric CPAP Continuous Positive Airway Pressure Ventilation Support System.
Additional Feature
- With inbuilt Air-oxygen blender.
- Compact, easy to carry with built in handle on the top.
- Can be used as transport CPAP, if attached to power-supply and oxygen.
- New concept free built-in air compressor easy BUBBLE CPAP.
- Low power design for spontaneous breathing of newborns and children, to provide continuous positive pressure ventilation support.
- Small size, low noise, maintenance-free for N ICU, transport, pediatric ward and other different place.
Infant Radiant Warmer – mLabs – NW
BRAND – mLabs
Advance micro processor controlled system with self check on the electronic circuitry Skin / Manual control. Digital Display of Baby Temperature / Set Temperature. Manual / Servo two function control modes provide the clinician more flexibility while optimizing the thermal environment. The Spacious baby bed incorporated easily drop down sides for maximum access to the baby. The Control Panel is also the heart for a completely integrated alarm system with both audible and visual Indicators in the event of
- Probe Fail
- Skin High
- Skin Low
- Power Fail
mLabs Phototherapy Unit 24 LED Double Surface
BRAND – mLabs
In the new born period i.e. birth to one month, jaundice can pose a serious problem, because high level of the bilirubin, which is not water soluble, can be decomposed to a harmless metabolic which is water soluble, does not cross blood brain barrier and is rapidly excreted in the bile and urine and so does not accumulate .
mLabs Phototherapy Unit 24 LED Single Surface
BRAND – mLabs
In the new born period i.e. birth to one month, jaundice can pose a serious problem, because high level of the bilirubin, which is not water soluble, can be decomposed to a harmless metabolic which is water soluble, does not cross blood brain barrier and is rapidly excreted in the bile and urine and so does not accumulate .
Oxygen Concentrator 10 Ltr.
* Flow Rate 0.10- 10L/min
* Outlet Pressure 6-10 PSI (0.04-0.07 Mpa)
* Net Weight 16Kgs
* Sound Level ≤40dB
* Power Consumption ≤350W
* Input Frequency 50Hz; 60Hz
* Put Voltage AC230V ± 10%; AC110V ±10%
* Alarm 1. Power failure alarm;
2. High and low pressure alarm;
3. Low oxygen purity alarm:
When oxygen purity is >82%, blue light illuminates;
When oxygen purity is < 82%, red light illuminates for indicating low purity;
4. Low flow alarm;
Optional
• Nebulizer (Atomizer)
• Low concentration alarm: when oxygen concentration is 82% or above, the green light will be on; when the oxygen concentration is blow 82%, the red light will be on.
• Maintenance alarm: alarm for maintenance after 3000 hours' operation.
• High temperature alarm: alarm for high temperature when the internal system temperature is above 50°C.
• Pulse oximeter: fingertip pulse oximeter is available for monitoring patient's oxygen saturation on site.
• Small LCD display: showing accumulated time, present working time and preset time.
Ophthalmic Operation Table
- Maximum Height – 800 mm
- Minimum Height – 600 mm
- Vertical Adjustment Range – 200 mm
- Total Length – 1880 mm
- Total Width – 690 mm
- Base Size – 920 mm x 535 mm
- Trendelenberg (head-low) – 6 Degrees
- Reverse tredelenberg – 5 Degrees
- Current – 230 v A/C -50 Hz
- Power Consumption – 340 VA
- Weight Capacity – 125 Kgs.
- Gross Weight – 160 Kgs.
Baby Bassinet
BRAND – mLabs
Baby bassinets have four-sided rail to prevent supplies from falling off and a shelf for linen and changing supplies.