Specifications:
Angle Rotor Head Capacity | Maximum Speed R.P.M. (on load) | Cat. No. |
6 x 200 ml. | 7000 | M-015 |
8 x 100 ml. | 7000 | M-016 |
12 x 50 ml. | 7000 | M-017 |
BRAND – mLabs
Maximum Speed | 20000 r.p.m |
Voltage | 200V |
Frequency | 50 Hz |
Specifications:
Angle Rotor Head Capacity | Maximum Speed R.P.M. (on load) | Cat. No. |
6 x 200 ml. | 7000 | M-015 |
8 x 100 ml. | 7000 | M-016 |
12 x 50 ml. | 7000 | M-017 |
BRAND – mLabs
It can match with imported and domestic ventilator, CPAP for heating and humidifying.
BRAND – mLabs
Advance micro processor controlled system with self check on the electronic circuitry Skin / Manual control. Digital Display of Baby Temperature / Set Temperature. Manual / Servo two function control modes provide the clinician more flexibility while optimizing the thermal environment. The Spacious baby bed incorporated easily drop down sides for maximum access to the baby. The Control Panel is also the heart for a completely integrated alarm system with both audible and visual Indicators in the event.
BRAND – mLabs
Baby Bassinet with a big shelf at the bottom for keeping consumables.
BRAND – mLabs
Range of mLabs– DX(E) Infant Radiant Warmer allow you to efficiently care and provide advance warming capabilities while using one touch operations to simplify procedures. Advance microprocessor controlled system with self-check on the electronic circuitry skin /air/ manual control.
BRAND – mLabs
Range of mLabs – D, open care system that comes in fiber and powder coated MS allow you to efficiently care and provide advance warming capabilities while using one touch operations to simplify procedures. Advance microprocessor controlled system with self-check on the electronic circuitry skin / air / manual control. Latest circuitry Skin/Air/Manual control. Latest technology packed with higher accuracy & enhanced visibility has been integrated in the system
* Flow Rate 0.10- 10L/min
* Outlet Pressure 6-10 PSI (0.04-0.07 Mpa)
* Net Weight 16Kgs
* Sound Level ≤40dB
* Power Consumption ≤350W
* Input Frequency 50Hz; 60Hz
* Put Voltage AC230V ± 10%; AC110V ±10%
* Alarm 1. Power failure alarm;
2. High and low pressure alarm;
3. Low oxygen purity alarm:
When oxygen purity is >82%, blue light illuminates;
When oxygen purity is < 82%, red light illuminates for indicating low purity;
4. Low flow alarm;
Optional
• Nebulizer (Atomizer)
• Low concentration alarm: when oxygen concentration is 82% or above, the green light will be on; when the oxygen concentration is blow 82%, the red light will be on.
• Maintenance alarm: alarm for maintenance after 3000 hours' operation.
• High temperature alarm: alarm for high temperature when the internal system temperature is above 50°C.
• Pulse oximeter: fingertip pulse oximeter is available for monitoring patient's oxygen saturation on site.
• Small LCD display: showing accumulated time, present working time and preset time.
BRAND – mLabs
Range of mLabs – DX open care systems allow you to efficiently care and provide advance warming capabilities while using one touch operations to simplify procedures. Advance microprocessor controlled system with self check on the electronic circuitry skin / air / manual control.
BRAND – mLabs
Newborn / Pediatric CPAP Continuous Positive Airway Pressure Ventilation Support System.
Additional Feature
BRAND – mLabs
Air Compressor with Digital Display
TECHNICAL SPECIFICATION :
BRAND – mLabs
In the new born period i.e. birth to one month, jaundice can pose a serious problem, because high level of the bilirubin, which is not water soluble, can be decomposed to a harmless metabolic which is water soluble, does not cross blood brain barrier and is rapidly excreted in the bile and urine and so does not accumulate .