- Power Supply: 220-240 VAC/50 Hz
- Operating Load: 100W
- Water Capacity – 1.5 Litre
- Dimensions (L x W x H) (13” x 13” x 15”)
mLabs-EH150 Humidifier
BRAND – mLabs
- Stainless Steel Body
- Evaporation 3-5 Ltr.P/H
- Water Pressure 5PSG
* Atomizing Capacity : 30-50 ml/min
* Manual timer (Optional)
* Float Valve (Optional)
* Uniform distribution
Related Products
Open Care System – mLabs – DX
BRAND – mLabs
Range of mLabs – DX open care systems allow you to efficiently care and provide advance warming capabilities while using one touch operations to simplify procedures. Advance microprocessor controlled system with self check on the electronic circuitry skin / air / manual control.
Open Care System – mLabs – D
BRAND – mLabs
Range of mLabs – D, open care system that comes in fiber and powder coated MS allow you to efficiently care and provide advance warming capabilities while using one touch operations to simplify procedures. Advance microprocessor controlled system with self-check on the electronic circuitry skin / air / manual control. Latest circuitry Skin/Air/Manual control. Latest technology packed with higher accuracy & enhanced visibility has been integrated in the system
Medical Air Compressor – mLabs – 1000
BRAND – mLabs
Air Compressor for Ventilator & Bubble CPAP
- Delivers dry, clean medical-grade compressed air
- Optional cost-performance ratio
- Quiet performance suitable for use in any ICU / N ICU
- It can be used either as a primary air source as a primary air source or as an automatic backup to a hospital’s air pipeline system for medical ventilator and bubble CPAP units
Bubble CPAP System – Restohealth mLabs – 01
BRAND – mLabs
- Able to give the baby a safe and controllable oxygen concentration.
- It is possible to effectively maintain the functional residual capacity.
- Can help reduce the breathing done by the baby.
- Can reduce the need for invasive mechanical ventilation.
- Able to give the baby a better wet gas.
- Can significantly reduce the incidence of chronic pneumonia (CLD).
- Can improve some of the lung physiological indicators, such as height, weight and so on.
Baby Bassinet
BRAND – mLabs
Baby bassinets have four-sided rail to prevent supplies from falling off and a shelf for linen and changing supplies.
Open Care System – mLabs – D2
BRAND – mLabs
Range of mLabs – D2 open care system that comes in fiber and powder coated MS, allow you to efficiently care and provide advance warming capabilities while using one touch operations to simplify procedures. Advance microprocessor controlled system with self-check on the electronic circuitry skin / air/ manual control. Latest technology packed with higher accuracy & enhanced visibility has been integrated in the system
Digital BOD Incubator
- Capacity – 150 Ltr.
- Temperature Range – 0 – 65oC
- Temperature Uniformity – + 0.5oC
- Temperature Resolution -0.1oC
- Working temperature – 5oC to 30oC
- Timer – 1-9999 min
- Refrigerant – R134A
- Power Wattage – 500 W
- Inner dimension (cm) WxDxH – 50x40x75
- Outer dimension (cm) WxDxH – 64x62x127
- Load per rack – 2 / 15kg
- Power Supply – 220 V / 50 Hz
- Gross Weight -97 kg
Respiratory Humidifier
BRAND – mLabs
It can match with imported and domestic ventilator, CPAP for heating and humidifying.
Baby Incubator mLabs – 1723D
BRAND – mLabs
- The temp. controlled unit is operated by advanced micro computer technology.
- The three digital display indication provide the Set Temperature, Air Temperature and Skin Temperature.
- Two function control modes provide the clinician more flexibility while optimizing the thermal environment.
- In addition the skin temperature is display is larger than the set / air temperature display.
- The removable heater and control unit make it easy to clean and service.
- Full visibility & accessibility of the baby is provided by the designed of acrylic hood.
Oxygen Concentrator 10 Ltr.
* Flow Rate 0.10- 10L/min
* Outlet Pressure 6-10 PSI (0.04-0.07 Mpa)
* Net Weight 16Kgs
* Sound Level ≤40dB
* Power Consumption ≤350W
* Input Frequency 50Hz; 60Hz
* Put Voltage AC230V ± 10%; AC110V ±10%
* Alarm 1. Power failure alarm;
2. High and low pressure alarm;
3. Low oxygen purity alarm:
When oxygen purity is >82%, blue light illuminates;
When oxygen purity is < 82%, red light illuminates for indicating low purity;
4. Low flow alarm;
Optional
• Nebulizer (Atomizer)
• Low concentration alarm: when oxygen concentration is 82% or above, the green light will be on; when the oxygen concentration is blow 82%, the red light will be on.
• Maintenance alarm: alarm for maintenance after 3000 hours' operation.
• High temperature alarm: alarm for high temperature when the internal system temperature is above 50°C.
• Pulse oximeter: fingertip pulse oximeter is available for monitoring patient's oxygen saturation on site.
• Small LCD display: showing accumulated time, present working time and preset time.
Infant Radiant Warmer – mLabs – S
BRAND – mLabs
The digital, micro processor – based controller comes with a full spectrum of features. Two function control modes provide the clinician more flexibility while optimizing the thermal environment. Dual digital temperature displays allow easy visualization of patient temperature and set point.
mLabs Phototherapy Unit 15 LED Single Surface
BRAND – mLabs
In the new born period i.e. birth to one month, jaundice can pose a serious problem, because high level of the bilirubin, which is not water soluble, can be decomposed to a harmless metabolic which is water soluble, does not cross blood brain barrier and is rapidly excreted in the bile and urine and so does not accumulate.