mLabs UV-VIS Spectrophotometer
BRAND – mLabs
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Spectral Bandwidth | 1 nm |
| Mobility | Benchtop |
| Brand | mLabs |
| Model No / Item Code | mLabs-4406 |
| Wavelength Accuracy | +-0.3 nm |
| Wavelength Repeatability | +-0.1 nm |
| Photometric Accuracy | +- 0.1% T |
| Photometric Range | -4 ABS ~TO 4 ABS |
| Photometric Repeatability | +- 0.3% T |
| Stray Light | Less than equal to 0.05%T |
| Stability | +- 0.001 A/h. |
| Detector | PHOTOMYLTIPLIER TUBE |
| Lamp Type | Deuterium Lamp, Tungsten Halogen Lamp |
| Grating | 1800 |
| Baseline Flatness | AUTOMATIC |
| Noise | 5000 |
| Data Output Port | USB |
| Sample Compartment | 2 CELL HOLDER |
| Material | Fiber / Plastic |
| Warranty | 1 YEAR |
| Operating Temperature | 50 |
| Country of Origin | Made in India |
mLabs Variable Double Beam Spectrophotometer
BRAND – mLabs
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Spectral Bandwidth | 0.5, 1,2,4,5 nm |
| Brand | mLabs |
| Model Name | Spectrophotometer |
| Photometric Accuracy | + 0.3 % T |
| Photometric Repeatability | + 0.2 % T |
| Stray Light | 0.05% T @ 220nm, 360 nm) |
| Stability | 0.001A/h @ 500 nm |
| Detector | Silicon Photodiode |
| Lamp Type | Deuterium Lamp, Tungsten Halogen Lamp |
| Display | Graphic LCD (320*240 Dots) |
| Country of Origin | Made in India |
| Noise | +0.001A |
| Data Output Port | USB |
| Baseline Flatness | + 0.001 A |
| Photometric Display Range | 0-200 % T, -0.3 – 3.0 A, 0-9999 C |
| Wavelength Reproducibility | 0.1 nm |
| Dimensions(L*W*H) | 630 x 430 x 206 mm |
| Net Weight | 26 Kg |
| Printer Port | Parallel Port |
| Scanning Speed | Fast / Medium / Slow |
mLabs VISION BOX ACUITY CHART MODULE
BRAND – mLabs
Digital Vision Box Module can convert your simple TV/Monitor to Vision Acuity Chart in only four steps –
– Connect TV/Monitor with Digital Vision Box through HDMI Cable
– Connect Digital Vision Box with 5V USB Power Supply
– Connect Power Supply to power outlet and turn on the device
– Switch the TV / Monitor to HDMI input
Your TV / Monitor is just converted to Digital Vision Chart
mLabs-2 Cell Double Beam UV VIS Spectrophotometer
BRAND – mLabs
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Spectral Bandwidth | 1 nm |
| Brand | mLabs |
| Model Name | Spectrophotometer |
| Wavelength Accuracy | +-0.3 nm |
| Wavelength Repeatability | +- 0.2 nm |
| Photometric Accuracy | +- 0.3% T |
| Photometric Range | 0-200 % T, -0.3-3.0 A, 0-9999 C |
| Stray Light | Less than equal to 0.05%T |
| Stability | +- 0.001 A/h. |
| Lamp Type | Halogen Lamp, Deuterium Lamp |
| Grating | 1200 lines / mm |
| Baseline Flatness | +- 0. 001 A/h |
| Data Output Port | USB Port |
| Display | 5 inches LCD (320×240 dots) |
| Dimensions | 580*510*210 mm |
| Printer Port | Parallel Port |
| Weight | 16 kg |
mLabs-20 pH Meter 3 Point Calibration
BRAND – mLabs
| Minimum Order Quantity | 1 Unit |
| Calibrated For | Manufacturer |
| Calibration Interval | One Time Requirement |
| Ph Meter Type | Benchtop Meter |
mLabs-52 DELUXE CONDUCTIVITY METER
BRAND – mLabs
| Usage/Application | Laboratory |
| Display Type | 3.5 DIGIT LED |
| Country of Origin | Made in India |
mLabs-8 Cell Holder Double Beam Spectrophotometer
BRAND – mLabs
| Optical System | Double Beam |
| Spectral Bandwidth | 1 nm |
| Model Name | Spectrophotometer |
| Photometric Accuracy | +- 0.3% T |
| Lamp Type | Deuterium Lamp, Halogen Lamp |
| Grating | 1200 lines / mm |
| Baseline Flatness | + 0.001 A |
| Noise | 0.0005 A |
| Data Output Port | USB Port |
| Display | 320 * 240 LCD |
| Dimensions | 580*510*210 mm |
| Wavelength Repeatability | 0.1 nm |
| Wavelength Accuracy | 0.3 nm |
| Stray Light | 0.05 % T |
| Stability | + 0.001 |
| Weight | 16 kg |
| Detector | Silicon Photodiode |
| Wavelength Scanning | Auto |
| Scanning Speed | Fast/Medium/Slow |
mLabs-Multi Vortexer
BRAND – mLabs
- The Surface of complete machine with stainless steel,no need to worry about any chemical corrosion .
- Maximum process 50 samples at the same time to make the experiment more convenient and efficient.
- Microprocessor control, simplistic designed appearance, LED display the speed and time.
- Humanized program design, built-in short mix ,continuous and timing operation modes. Operation stable and silent. Include the standard foam rack with diameter 50X15ml tube Various types of foam tube rack and pads for option.
Multi Tube Vortex Mixer
- Brushless DC motor for quiet operation and maintenance free long operation.
- Microprocessor controlled unit with digital display.
- Adjustable speed ranging from 300-2500 RPM with increment of 1 RPM and accuracy of +/-5 RPM with option of electing Clockwise (CW) and Counterclockwise (CCW) motion
- Long timer setting from 1 to 999 mins & infinite mode.
- Power Overload feature in which if the equipment consumes more power than its capacity, it automatically shuts down.
- Supplied with all six foam base attachments
Open Care System – mLabs – D
BRAND – mLabs
Range of mLabs – D, open care system that comes in fiber and powder coated MS allow you to efficiently care and provide advance warming capabilities while using one touch operations to simplify procedures. Advance microprocessor controlled system with self-check on the electronic circuitry skin / air / manual control. Latest circuitry Skin/Air/Manual control. Latest technology packed with higher accuracy & enhanced visibility has been integrated in the system
Open Care System – mLabs – D2
BRAND – mLabs
Range of mLabs – D2 open care system that comes in fiber and powder coated MS, allow you to efficiently care and provide advance warming capabilities while using one touch operations to simplify procedures. Advance microprocessor controlled system with self-check on the electronic circuitry skin / air/ manual control. Latest technology packed with higher accuracy & enhanced visibility has been integrated in the system