Nucleic Acid Extraction System
Model | NAES-081 |
Nucleic Acid Extraction System
Model | NAES-081 |
Product features
• This product adopts 100% natural high-quality cotton, silky texture. After high-temperature treatment, clean cotton and plastic stick tightly entangled. Let you feel at ease easily in use.
•Features: Effectively absorbent cotton swab with high-quality cotton wool. Low dust loading, high grade of dust-free, high density of cotton head and no easy to fall off.
•The plastic stick is with suitable firmness and high resilience, also not easy to break.
Contents :
Specification:
Model No | mLabs 05S |
Body temperature range | 32 to 43℃(90 to 109℉) |
Operating temperature | 10 to 40℃(50 to 104℉) |
Accuracy | ±0.3℃(±0.6℉) |
Surface temperature range | 0 to 100℃(32 to 212℉) |
Surface temperature accuracy | 1℃(33.8℉) |
Measuring distance | 5~15cm(2in~5.9in) |
Spectral response | 6~14um |
Automatic stop | 7 second |
Size | 180*100*46mm |
Weight | 160g |
Accessories | 9V battery, manual & black bag |
The product that revolutionised hand hygiene back in 1965 has been developed over the past decades into a portfolio of quality products for HARTMANN to be able to rise to all the challenges in routine, high-risk and outbreak situations. Ready-to-use alcohol-based Sterillium® products for hand disinfection are characterised by:
* Extra layer of protection while intubating a patient
* Transparent acrylic provides clear visibility from all angles
* Arm holes provide easy access to patient’s airway
* Easily cleaned and disinfected
Model | ML/VA-22 | ML/VA-40 | ML/VA-50 | ML/VA-95 | ML/VA-175 |
---|---|---|---|---|---|
Internal Tank Capacity | 22 Liter | 40 Liter | 50 Liter | 95 Liter | 175 Liter |
Load | 2.00 KW | 3.00 KW | 3.00 KW | 4.00 KW | 6.00 KW |
Chamber dimension | 10” x 18” | 12” x 22” | 14” x 22” | 18” x 24” | 22” x 36” |
No.of Drums & Sizes | – | 2 (9” x11”) | 2 (9” x11”) | 2 (12” x 15”) | 3 (12” x 15”) |
Working Pressure | 1.2 kgf/cm sq.g (15 psi – 17 psi) (Can be Upgraded up to 30 PSI) | ||||
Sterilizing Temperature | 121°C to 134°C (150°C – Optional) | ||||
Heat Average | <=±1°C | ||||
Sterilization Time | 25 to 30 Minutes | ||||
Digital Timer | 0 to 99 min | ||||
Construction | Double / Triple wall & SS GMP construction | ||||
Outer Chamber | Mild Steel (304 stainless Steel – Optional) | ||||
Inner Chamber | 304 SS (316 / 316L grades Stainless Steel – Optional) | ||||
Insulation | Glass Wool | ||||
Waste Container | Stainless Steel | ||||
Door / Lid | Foot lifted with safety and interlock device | ||||
Door Locking type | Radial Type (Wing Nut Optional) | ||||
Water Filling & Removal | Manual | ||||
Safety Features | Radial locking, safety valve, low water detector and pressure interlock | ||||
Optional accessories | – PID controller – Low / High water cut-off device – Digital alarm – Temperature chart recorder – Dot Matrix Printer – RS 232 / USB PC Connection Port – NABL certification – Stainless Steel wire mesh carrier – Dressing drum – Sterilization indicator tape – Autoclave bags – PLC control system – IQ / OQ / PQ Documentation |
||||
Power Supply | 220 Volts / 440 Volts |