- Take test tube fill water sample to be tested up to 5 ml. Mark.
- Add 1 to 2 drop of O-Quinidine solution into the sample with the help of a dropper.
- Shake well and keep the tube for ten minutes to develop the color. Compare the developed color with Choloroscope
- As soon as the color is developed match the color by inserting the tube in 1st or 2nd or 3rd hole and examine from color standard and note down the reading of same from PPM scale marked in front of Chloroscope.
- When testing is completed, pour out the sample, clean the tube with fresh water and with the help of cleaning brush.
Chloroscope Water Testing Kit
BRAND – mLabs
| Usage | Public Health Depts., Water Testing Labs, swimming pools, Industrial Labs |
| Chlorine amount in Water | 0.25 p.p.m. to 2.0 p.p.m. |
| Brand | mLabs |
Related Products
6 Mobile OT Light
TECHNICAL SPECIFICATION :
- Number of LED: 84
- Intensity: 180,000 Lux
- Diameter of Light: 650mm
- Color Temperature: 3800-5200K
- Spot Diameter: 100 -150 mm
- Color Rendering Index: 91 RA
- LED color: white & yellow
- Focusing: Adjustable
- LED Average Life: More than 50000 Hrs
- Intensity Control: 10-100 Digital
- Power Supply: 220V / 50Hz AC
- Power: 150 Watt
- Special Function: 5 Memory Function with remote control & brightness control
Digital Refrigerated Centrifuge Machine
BRAND – mLabs
| Max. Speed | 18000 rpm |
| Voltage | 220v |
| Frequency | 50 Hz |
Open Care System – mLabs – D2
BRAND – mLabs
Range of mLabs – D2 open care system that comes in fiber and powder coated MS, allow you to efficiently care and provide advance warming capabilities while using one touch operations to simplify procedures. Advance microprocessor controlled system with self-check on the electronic circuitry skin / air/ manual control. Latest technology packed with higher accuracy & enhanced visibility has been integrated in the system
Oxygen Concentrator 10 Ltr.
* Flow Rate 0.10- 10L/min
* Outlet Pressure 6-10 PSI (0.04-0.07 Mpa)
* Net Weight 16Kgs
* Sound Level ≤40dB
* Power Consumption ≤350W
* Input Frequency 50Hz; 60Hz
* Put Voltage AC230V ± 10%; AC110V ±10%
* Alarm 1. Power failure alarm;
2. High and low pressure alarm;
3. Low oxygen purity alarm:
When oxygen purity is >82%, blue light illuminates;
When oxygen purity is < 82%, red light illuminates for indicating low purity;
4. Low flow alarm;
Optional
• Nebulizer (Atomizer)
• Low concentration alarm: when oxygen concentration is 82% or above, the green light will be on; when the oxygen concentration is blow 82%, the red light will be on.
• Maintenance alarm: alarm for maintenance after 3000 hours' operation.
• High temperature alarm: alarm for high temperature when the internal system temperature is above 50°C.
• Pulse oximeter: fingertip pulse oximeter is available for monitoring patient's oxygen saturation on site.
• Small LCD display: showing accumulated time, present working time and preset time.
Table Top Centrifuge Machine
BRAND – mLabs
| Maximum Speed | 20000 r.p.m |
| Voltage | 200V |
| Frequency | 50 Hz |
Infant Radiant Warmer – mLabs – NWDX
BRAND – mLabs
Advance micro processor controlled system with self check on the electronic circuitry Skin / Manual control. Digital Display of Baby Temperature / Set Temperature. Manual / Servo two function control modes provide the clinician more flexibility while optimizing the thermal environment. The Spacious baby bed incorporated easily drop down sides for maximum access to the baby. The Control Panel is also the heart for a completely integrated alarm system with both audible and visual Indicators in the event.
Infant Radiant Warmer – mLabs – NW
BRAND – mLabs
Advance micro processor controlled system with self check on the electronic circuitry Skin / Manual control. Digital Display of Baby Temperature / Set Temperature. Manual / Servo two function control modes provide the clinician more flexibility while optimizing the thermal environment. The Spacious baby bed incorporated easily drop down sides for maximum access to the baby. The Control Panel is also the heart for a completely integrated alarm system with both audible and visual Indicators in the event of
- Probe Fail
- Skin High
- Skin Low
- Power Fail
Microprocessor Based Centrifuge Machine
BRAND – mLabs
| Max Speed | 5200 rpm |
| Motor | Universal Motor |
| Power | AC 220 V, 50 Hz |
Infant Radiant Warmer – mLabs – IRW 1723
BRAND – mLabs
Advance micro processor controlled system with self check on the electronic circuitry skin / Air Manual control. Digital display of baby temperature.
Micro Centrifuge
BRAND – mLabs
| Voltage | 220v |
| Maximum Speed | 16000 rpm |
| Frequency | 50 Hz |
Micro Centrifuge High Speed
BRAND – mLabs
| Max. Speed | 16000 rpm |
| Voltage | 220v |
| Frequency | 50 Hz |
Baby Incubator mLabs – 1723D
BRAND – mLabs
- The temp. controlled unit is operated by advanced micro computer technology.
- The three digital display indication provide the Set Temperature, Air Temperature and Skin Temperature.
- Two function control modes provide the clinician more flexibility while optimizing the thermal environment.
- In addition the skin temperature is display is larger than the set / air temperature display.
- The removable heater and control unit make it easy to clean and service.
- Full visibility & accessibility of the baby is provided by the designed of acrylic hood.