- Take test tube fill water sample to be tested up to 5 ml. Mark.
- Add 1 to 2 drop of O-Quinidine solution into the sample with the help of a dropper.
- Shake well and keep the tube for ten minutes to develop the color. Compare the developed color with Choloroscope
- As soon as the color is developed match the color by inserting the tube in 1st or 2nd or 3rd hole and examine from color standard and note down the reading of same from PPM scale marked in front of Chloroscope.
- When testing is completed, pour out the sample, clean the tube with fresh water and with the help of cleaning brush.
Chloroscope Water Testing Kit
BRAND – mLabs
Usage | Public Health Depts., Water Testing Labs, swimming pools, Industrial Labs |
Chlorine amount in Water | 0.25 p.p.m. to 2.0 p.p.m. |
Brand | mLabs |
Related Products
mLabs Phototherapy Unit 15 LED Single Surface
BRAND – mLabs
In the new born period i.e. birth to one month, jaundice can pose a serious problem, because high level of the bilirubin, which is not water soluble, can be decomposed to a harmless metabolic which is water soluble, does not cross blood brain barrier and is rapidly excreted in the bile and urine and so does not accumulate.
Microprocessor Based Centrifuge Machine
BRAND – mLabs
Max Speed | 5200 rpm |
Motor | Universal Motor |
Power | AC 220 V, 50 Hz |
Open Care System – mLabs – DX
BRAND – mLabs
Range of mLabs – DX open care systems allow you to efficiently care and provide advance warming capabilities while using one touch operations to simplify procedures. Advance microprocessor controlled system with self check on the electronic circuitry skin / air / manual control.
Infant Radiant Warmer
Advance micro processor controlled system with self check on the electronic circuitry Skin / Manual control. Digital Display of Baby Temperature / Set Temperature. Manual / Servo two function control modes provide the clinician more flexibility while optimizing the thermal environment. The Spacious baby bed incorporated easily drop down sides for maximum access to the baby. The Control Panel is also the heart for a completely integrated alarm system with both audible and visual Indicators in the event of
* Probe Fail
* Skin High
* Skin Low
* Power Fail
Oxygen Concentrator 10 Ltr.
* Flow Rate 0.10- 10L/min
* Outlet Pressure 6-10 PSI (0.04-0.07 Mpa)
* Net Weight 16Kgs
* Sound Level ≤40dB
* Power Consumption ≤350W
* Input Frequency 50Hz; 60Hz
* Put Voltage AC230V ± 10%; AC110V ±10%
* Alarm 1. Power failure alarm;
2. High and low pressure alarm;
3. Low oxygen purity alarm:
When oxygen purity is >82%, blue light illuminates;
When oxygen purity is < 82%, red light illuminates for indicating low purity;
4. Low flow alarm;
Optional
• Nebulizer (Atomizer)
• Low concentration alarm: when oxygen concentration is 82% or above, the green light will be on; when the oxygen concentration is blow 82%, the red light will be on.
• Maintenance alarm: alarm for maintenance after 3000 hours' operation.
• High temperature alarm: alarm for high temperature when the internal system temperature is above 50°C.
• Pulse oximeter: fingertip pulse oximeter is available for monitoring patient's oxygen saturation on site.
• Small LCD display: showing accumulated time, present working time and preset time.
mLabs Phototherapy Unit 24 LED Double Surface
BRAND – mLabs
In the new born period i.e. birth to one month, jaundice can pose a serious problem, because high level of the bilirubin, which is not water soluble, can be decomposed to a harmless metabolic which is water soluble, does not cross blood brain barrier and is rapidly excreted in the bile and urine and so does not accumulate .
Mini Centrifuge Machine
BRAND – mLabs
Maximum Speed | 10000 rpm |
Voltage | 220v |
Frequency | 60 Hz |
mLabs Phototherapy Unit 15 LED Double Surface
BRAND – mLabs
In the new born period i.e. birth to one month, jaundice can pose a serious problem, because high level of the bilirubin, which is not water soluble, can be decomposed to a harmless metabolic which is water soluble, does not cross blood brain barrier and is rapidly excreted in the bile and urine and so does not accumulate.
Open Care System – mLabs – D
BRAND – mLabs
Range of mLabs – D, open care system that comes in fiber and powder coated MS allow you to efficiently care and provide advance warming capabilities while using one touch operations to simplify procedures. Advance microprocessor controlled system with self-check on the electronic circuitry skin / air / manual control. Latest circuitry Skin/Air/Manual control. Latest technology packed with higher accuracy & enhanced visibility has been integrated in the system
Bubble CPAP Machine – Restohealth mLabs – 03
BRAND – mLabs
Newborn / Pediatric CPAP Continuous Positive Airway Pressure Ventilation Support System.
Additional Feature
- With inbuilt Air-oxygen blender.
- Compact, easy to carry with built in handle on the top.
- Can be used as transport CPAP, if attached to power-supply and oxygen.
- New concept free built-in air compressor easy BUBBLE CPAP.
- Low power design for spontaneous breathing of newborns and children, to provide continuous positive pressure ventilation support.
- Small size, low noise, maintenance-free for N ICU, transport, pediatric ward and other different place.
Infant Radiant Warmer – mLabs – S
BRAND – mLabs
The digital, micro processor – based controller comes with a full spectrum of features. Two function control modes provide the clinician more flexibility while optimizing the thermal environment. Dual digital temperature displays allow easy visualization of patient temperature and set point.
Baby Bassinet
BRAND – mLabs
Baby bassinets have four-sided rail to prevent supplies from falling off and a shelf for linen and changing supplies.