Ultra Thin Research U.V Transilluminator is Very small Portable, very accurate for research work. And It has Aluminium pressure die casted body furnished in Pink powder coating
Ultra Thin Research U.V Transilluminator
BRAND – mLabs
Wavelength | 302 nm |
No. of Tubes | 4 |
Wattage | 8 Watts |
Detection limit | 0.01 gm of stained DNA. |
View area | 150×80 mm |
Filter | Quartz UV filter |
UV Protection Shield | Yes |
Related Products
mLabs Phototherapy Unit 15 LED Single Surface
BRAND – mLabs
In the new born period i.e. birth to one month, jaundice can pose a serious problem, because high level of the bilirubin, which is not water soluble, can be decomposed to a harmless metabolic which is water soluble, does not cross blood brain barrier and is rapidly excreted in the bile and urine and so does not accumulate.
Resuscitation Trolley
BRAND – mLabs
Baby Bassinet with a big shelf at the bottom for keeping consumables.
Open Care System – mLabs – D2
BRAND – mLabs
Range of mLabs – D2 open care system that comes in fiber and powder coated MS, allow you to efficiently care and provide advance warming capabilities while using one touch operations to simplify procedures. Advance microprocessor controlled system with self-check on the electronic circuitry skin / air/ manual control. Latest technology packed with higher accuracy & enhanced visibility has been integrated in the system
Infant Radiant Warmer – mLabs – IRW 1723
BRAND – mLabs
Advance micro processor controlled system with self check on the electronic circuitry skin / Air Manual control. Digital display of baby temperature.
Infant Radiant Warmer – mLabs – DX (E)
BRAND – mLabs
Range of mLabs– DX(E) Infant Radiant Warmer allow you to efficiently care and provide advance warming capabilities while using one touch operations to simplify procedures. Advance microprocessor controlled system with self-check on the electronic circuitry skin /air/ manual control.
Bubble CPAP System – Restohealth mLabs – 01
BRAND – mLabs
- Able to give the baby a safe and controllable oxygen concentration.
- It is possible to effectively maintain the functional residual capacity.
- Can help reduce the breathing done by the baby.
- Can reduce the need for invasive mechanical ventilation.
- Able to give the baby a better wet gas.
- Can significantly reduce the incidence of chronic pneumonia (CLD).
- Can improve some of the lung physiological indicators, such as height, weight and so on.
Infant Radiant Warmer – mLabs – NW
BRAND – mLabs
Advance micro processor controlled system with self check on the electronic circuitry Skin / Manual control. Digital Display of Baby Temperature / Set Temperature. Manual / Servo two function control modes provide the clinician more flexibility while optimizing the thermal environment. The Spacious baby bed incorporated easily drop down sides for maximum access to the baby. The Control Panel is also the heart for a completely integrated alarm system with both audible and visual Indicators in the event of
- Probe Fail
- Skin High
- Skin Low
- Power Fail
Oxygen Concentrator 5 Ltr.
* Flow Rate 0.5-5L/min
* Outlet Pressure 6-10 PSI (0.04-0.07 Mpa)
* Net Weight 16Kgs
* Sound Level ≤40dB
* Power Consumption ≤350W
* Input Frequency 50Hz; 60Hz
* Put Voltage AC230V ± 10%; AC110V ±10%
* Alarm 1. Power failure alarm;
2. High and low pressure alarm;
3. Low oxygen purity alarm:
When oxygen purity is >82%, blue light illuminates;
When oxygen purity is < 82%, red light illuminates for indicating low purity;
4. Low flow alarm;
Optional
• Nebulizer (Atomizer)
• Low concentration alarm: when oxygen concentration is 82% or above, the green light will be on; when the oxygen concentration is blow 82%, the red light will be on.
• Maintenance alarm: alarm for maintenance after 3000 hours' operation.
• High temperature alarm: alarm for high temperature when the internal system temperature is above 50°C.
• Pulse oximeter: fingertip pulse oximeter is available for monitoring patient's oxygen saturation on site.
• Small LCD display: showing accumulated time, present working time and preset time.
Medical Air Compressor – mLabs – 3000
BRAND – mLabs
Air Compressor with Digital Display
- Delivers dry, clean medical-grade compressed air
- Optional cost-performance ratio
- Quiet performance suitable for use in any ICU / N ICU
- It can be used either as a primary air source or as an automatic backup to a hospital’s air pipeline system for medical ventilator and bubble CPAP units
Double Dome Ceiling OT Light
Technical Data
- Number of LED : 105 X2
- Intensity : 2,00,000 x 2 Lux
- Diameter of Light : 10-100 Digital
- Spot Diameter : 100- 150 mm
- Depth Lumination – 10-15cm
- Colour Temp. : 3800-5200K
- Colour Rendering Index : 91 Ra
- Focusing : Fix
- LED Average Life : >50000 Hrs.
- Intensity Control : 560mm X 2
- Power Supply : 220V/50Hz AC
- Power : 120 Watt X 2
- Special Function : 5 Memory Function
Colour Specification – Multi Colour
Positioning – Ceiling Mounted,Modular,Mobile,Wall Mounted
6 Mobile OT Light
TECHNICAL SPECIFICATION :
- Number of LED: 84
- Intensity: 180,000 Lux
- Diameter of Light: 650mm
- Color Temperature: 3800-5200K
- Spot Diameter: 100 -150 mm
- Color Rendering Index: 91 RA
- LED color: white & yellow
- Focusing: Adjustable
- LED Average Life: More than 50000 Hrs
- Intensity Control: 10-100 Digital
- Power Supply: 220V / 50Hz AC
- Power: 150 Watt
- Special Function: 5 Memory Function with remote control & brightness control
Oxygen Concentrator 10 Ltr.
* Flow Rate 0.10- 10L/min
* Outlet Pressure 6-10 PSI (0.04-0.07 Mpa)
* Net Weight 16Kgs
* Sound Level ≤40dB
* Power Consumption ≤350W
* Input Frequency 50Hz; 60Hz
* Put Voltage AC230V ± 10%; AC110V ±10%
* Alarm 1. Power failure alarm;
2. High and low pressure alarm;
3. Low oxygen purity alarm:
When oxygen purity is >82%, blue light illuminates;
When oxygen purity is < 82%, red light illuminates for indicating low purity;
4. Low flow alarm;
Optional
• Nebulizer (Atomizer)
• Low concentration alarm: when oxygen concentration is 82% or above, the green light will be on; when the oxygen concentration is blow 82%, the red light will be on.
• Maintenance alarm: alarm for maintenance after 3000 hours' operation.
• High temperature alarm: alarm for high temperature when the internal system temperature is above 50°C.
• Pulse oximeter: fingertip pulse oximeter is available for monitoring patient's oxygen saturation on site.
• Small LCD display: showing accumulated time, present working time and preset time.